Surfaces Requiring Special Treatment
Dimensional or Mechanical Changes Due to
Surface Preparation
For most materials, strain measurement results
are usually not significantly changed by the
surface preparation procedures described in this
publication. Even with appreciable material
removal, effects on the static mechanical
properties of the test part are generally
negligible compared to other error sources in the
experiment. It should be understood, however, that
removal of a plated or hardened surface layer, or
of a surface layer with significant residual
stresses, may noticeably affect the fatigue life or
the wear characteristics of the part when operated
under dynamic service conditions.
Page 20 of 23
|