Gage Bonding
This sequence covers bonding of polyimide-backed strain gages with Micro-Measurements
EA-Series
using
M-Bond 200
cyanoacrylate adhesive.
Five basic operations are required:
Gage Preparation
Gage Transfer
Catalyst Application
Gage Bonding
Tape Removal
Prior to performing these operations, the surface must be
properly prepared
. In this case the specimen is an aluminum alloy beam.
Page 1 of 11