Brands     Vishay Measurements Group     Interactive Guide     Tech Notes     TN-505

SD-Series Gages

Description and Primary Application

Fully encapsulated isoelastic gages with solder dots. Used in wide-range dynamic strain measurement applications in severe environments.


Temperature Range

Dynamic: -320 deg to +500 deg F (-195 deg to +260 deg C)

Strain Range

+ 1.5%
Nonlinear at strain levels over + 0.5%

Fatigue Life

10 6 cycles at + 2500 microstrain
10 7 cycles at + 2200 microstrain



Please note : The performance data given here are nominal , and apply primarily to gages of 0.125-in (3-mm) gage length or larger.



Reference Table