Brands     Vishay Measurements Group     Interactive Guide     Tech Tips     TT-602


Silver Solder Technique
for Attachment of Leads to Strain Gages

Cable Anchoring

Step 1

Clip off the excess gage leads and instrument leadwires at the solder joint, and remove the drafting tape .

Step 2

Carefully form the leadwires flat against the surface and hold in place with Mylar tape or wire. Secure with tape as shown below.




Page 14 of 16