Techniques for Attaching
Leadwires
to Unbonded Strain Gages
|
Gage Removal and Cleaning
- After soldering has been completed, thoroughly
flood the gage and tape area with several brush
applications of
RSK Rosin
Solvent
.
- Work the solvent brush around solder areas and
under tape. Do not try to lift gage/leadwire
assembly until rosin solvent has loosened tape from
gage face.
- Lift gage assembly by the leadwires and dip
into a container of clean rosin solvent. Scrub the
solder connections and gage face with brush
provided with the rosin solvent.
- Remove assembly from rosin solvent and blot dry
between layers of
gauze
sponges
. Use caution not to snag gauze on gage backing or
solder connections.
- Place gage on a clean work surface with the
bonding surface exposed. Wipe with a
cotton
applicator
slightly moistened with
Neutralizer
5A
. Rolling the cotton applicator as you wipe will
improve cleansing. Allow to air dry 5 minutes.
- Slip cleaned gage into acetate folder and tape
shut. This will minimize contamination and provide
lead support until ready for installation.
Page 9 of 10
|
|