Part number
Product Image
Package
Dimensions
(mm)
Carrier Frequency
(kHz)
AGC
Transmission Distance Typ.
(m)
Detection Threshold / Sensitivity Typ.
Viewing Angle
()
Supply Current Typ.
Pinning
Remote Control Code
Application
Mounting
Datasheet
Minimold 5.4 W x 6.35 H x 4.9 D 30 AGC1 45 0.08 45 0.35 1 = OUT, 2 = GND, 3 = VS Remote control Leaded
Datasheet
Minimold 5.4 W x 6.35 H x 4.9 D 30 AGC1 45 0.12 45 0.7 1 = OUT, 2 = GND, 3 = VS Remote control Leaded
Datasheet
Minimold 5.4 W x 6.35 H x 4.9 D 33 AGC1 45 0.08 45 0.35 1 = OUT, 2 = GND, 3 = VS Remote control Leaded
Datasheet
Minimold 5.4 W x 6.35 H x 4.9 D 33 AGC1 45 0.12 45 0.7 1 = OUT, 2 = GND, 3 = VS Remote control Leaded
Datasheet
Minimold 5.4 W x 6.35 H x 4.9 D 36 AGC1 45 0.08 45 0.35 1 = OUT, 2 = GND, 3 = VS Remote control Leaded
Datasheet
Minimold 5.4 W x 6.35 H x 4.9 D 36 AGC1 45 0.12 45 0.7 1 = OUT, 2 = GND, 3 = VS Remote control Leaded
Datasheet
Minimold 5.4 W x 6.35 H x 4.9 D 38 AGC1 45 0.08 45 0.35 1 = OUT, 2 = GND, 3 = VS Remote control Leaded
Datasheet
Minimold 5.4 W x 6.35 H x 4.9 D 38 AGC1 45 0.12 45 0.7 1 = OUT, 2 = GND, 3 = VS Remote control Leaded
Datasheet
Minimold 5.4 W x 6.35 H x 4.9 D 40 AGC1 45 0.08 45 0.35 1 = OUT, 2 = GND, 3 = VS Remote control Leaded
Datasheet
Minimold 5.4 W x 6.35 H x 4.9 D 40 AGC1 45 0.12 45 0.7 1 = OUT, 2 = GND, 3 = VS Remote control Leaded
Datasheet
Minimold 5.4 W x 6.35 H x 4.9 D 56 AGC1 45 0.08 45 0.35 1 = OUT, 2 = GND, 3 = VS Remote control Leaded
Datasheet
Minimold 5.4 W x 6.35 H x 4.9 D 56 AGC1 45 0.12 45 0.7 1 = OUT, 2 = GND, 3 = VS Remote control Leaded
Datasheet
Minimold 5.4 W x 6.35 H x 4.9 D 30 AGC2 45 0.08 45 0.35 1 = OUT, 2 = GND, 3 = VS Remote control Leaded
Datasheet
Minimold 5.4 W x 6.35 H x 4.9 D 30 AGC2 45 0.12 45 0.7 1 = OUT, 2 = GND, 3 = VS Remote control Leaded
Datasheet
Minimold 5.4 W x 6.35 H x 4.9 D 33 AGC2 45 0.08 45 0.35 1 = OUT, 2 = GND, 3 = VS Remote control Leaded
Datasheet
Minimold 5.4 W x 6.35 H x 4.9 D 33 AGC2 45 0.12 45 0.7 1 = OUT, 2 = GND, 3 = VS Remote control Leaded
Datasheet
Minimold 5.4 W x 6.35 H x 4.9 D 36 AGC2 45 0.08 45 0.35 1 = OUT, 2 = GND, 3 = VS Remote control Leaded
Datasheet
Minimold 5.4 W x 6.35 H x 4.9 D 36 AGC2 45 0.12 45 0.7 1 = OUT, 2 = GND, 3 = VS Remote control Leaded
Datasheet
Minimold 5.4 W x 6.35 H x 4.9 D 38 AGC2 45 0.08 45 0.35 1 = OUT, 2 = GND, 3 = VS Remote control Leaded
Datasheet
Minimold 5.4 W x 6.35 H x 4.9 D 38 AGC2 45 0.12 45 0.7 1 = OUT, 2 = GND, 3 = VS Remote control Leaded
Datasheet
Minimold 5.4 W x 6.35 H x 4.9 D 40 AGC2 45 0.08 45 0.35 1 = OUT, 2 = GND, 3 = VS Remote control Leaded
Datasheet
Minimold 5.4 W x 6.35 H x 4.9 D 40 AGC2 45 0.12 45 0.7 1 = OUT, 2 = GND, 3 = VS Remote control Leaded
Datasheet
Minimold 5.4 W x 6.35 H x 4.9 D 56 AGC2 45 0.08 45 0.35 1 = OUT, 2 = GND, 3 = VS Remote control Leaded
Datasheet
Minimold 5.4 W x 6.35 H x 4.9 D 56 AGC2 45 0.12 45 0.7 1 = OUT, 2 = GND, 3 = VS Remote control Leaded
Datasheet
Minimold 5.4 W x 6.35 H x 4.9 D 30 AGC3 45 0.08 45 0.35 1 = OUT, 2 = GND, 3 = VS Remote control Leaded
Datasheet
Minimold 5.4 W x 6.35 H x 4.9 D 30 AGC3 45 0.12 45 0.7 1 = OUT, 2 = GND, 3 = VS Remote control Leaded
Datasheet
Minimold 5.4 W x 6.35 H x 4.9 D 33 AGC3 45 0.08 45 0.35 1 = OUT, 2 = GND, 3 = VS Remote control Leaded
Datasheet
Minimold 5.4 W x 6.35 H x 4.9 D 33 AGC3 45 0.12 45 0.7 1 = OUT, 2 = GND, 3 = VS Remote control Leaded
Datasheet
Minimold 5.4 W x 6.35 H x 4.9 D 36 AGC3 45 0.08 45 0.35 1 = OUT, 2 = GND, 3 = VS MCIR, RCMM Remote control Leaded
Datasheet
Minimold 5.4 W x 6.35 H x 4.9 D 36 AGC3 45 0.12 45 0.7 1 = OUT, 2 = GND, 3 = VS MCIR Remote control Leaded
Datasheet
Minimold 5.4 W x 6.35 H x 4.9 D 38 AGC3 45 0.08 45 0.35 1 = OUT, 2 = GND, 3 = VS Mitsubishi, RECS-80 Code, r-map, XMP-1 XMP-2 Remote control Leaded
Datasheet
Minimold 5.4 W x 6.35 H x 4.9 D 38 AGC3 45 0.12 45 0.7 1 = OUT, 2 = GND, 3 = VS Mitsubishi, RECS-80 Code, r-map, XMP-1 Remote control Leaded
Datasheet
Minimold 5.4 W x 6.35 H x 4.9 D 40 AGC3 45 0.08 45 0.35 1 = OUT, 2 = GND, 3 = VS Remote control Leaded
Datasheet
Minimold 5.4 W x 6.35 H x 4.9 D 40 AGC3 45 0.12 45 0.7 1 = OUT, 2 = GND, 3 = VS Remote control Leaded
Datasheet
Minimold 5.4 W x 6.35 H x 4.9 D 56 AGC3 45 0.08 45 0.35 1 = OUT, 2 = GND, 3 = VS Remote control Leaded
Datasheet
Minimold 5.4 W x 6.35 H x 4.9 D 56 AGC3 45 0.12 45 0.7 1 = OUT, 2 = GND, 3 = VS Remote control Leaded
Datasheet
Minimold 5.4 W x 6.35 H x 4.9 D 30 AGC4 45 0.08 45 0.35 1 = OUT, 2 = GND, 3 = VS Remote control Leaded
Datasheet
Minimold 5.4 W x 6.35 H x 4.9 D 30 AGC4 45 0.12 45 0.7 1 = OUT, 2 = GND, 3 = VS Remote control Leaded
Datasheet
Minimold 5.4 W x 6.35 H x 4.9 D 33 AGC4 45 0.08 45 0.35 1 = OUT, 2 = GND, 3 = VS Remote control Leaded
Datasheet
Minimold 5.4 W x 6.35 H x 4.9 D 33 AGC4 45 0.12 45 0.7 1 = OUT, 2 = GND, 3 = VS Remote control Leaded
Datasheet
Minimold 5.4 W x 6.35 H x 4.9 D 36 AGC4 45 0.08 45 0.35 1 = OUT, 2 = GND, 3 = VS RC-5, RC-6, Panasonic Remote control Leaded
Datasheet
Minimold 5.4 W x 6.35 H x 4.9 D 36 AGC4 45 0.12 45 0.7 1 = OUT, 2 = GND, 3 = VS RC-5, RC-6, Panasonic Remote control Leaded
Datasheet
Minimold 5.4 W x 6.35 H x 4.9 D 38 AGC4 45 0.08 45 0.35 1 = OUT, 2 = GND, 3 = VS NEC, Sharp Remote control Leaded
Datasheet
Minimold 5.4 W x 6.35 H x 4.9 D 38 AGC4 45 0.12 45 0.7 1 = OUT, 2 = GND, 3 = VS NEC, Sharp Remote control Leaded
Datasheet
Minimold 5.4 W x 6.35 H x 4.9 D 40 AGC4 45 0.08 45 0.35 1 = OUT, 2 = GND, 3 = VS Remote control Leaded
Datasheet
Minimold 5.4 W x 6.35 H x 4.9 D 40 AGC4 45 0.12 45 0.7 1 = OUT, 2 = GND, 3 = VS Remote control Leaded
Datasheet
Minimold 5.4 W x 6.35 H x 4.9 D 56 AGC4 45 0.08 45 0.35 1 = OUT, 2 = GND, 3 = VS r-step, Thomson RCA Remote control Leaded
Datasheet
Minimold 5.4 W x 6.35 H x 4.9 D 56 AGC4 45 0.12 45 0.7 1 = OUT, 2 = GND, 3 = VS r-step, Thomson RCA Remote control Leaded
Datasheet
Minimold 5.4 W x 6.35 H x 4.9 D 30 AGC5 45 0.08 45 0.35 1 = OUT, 2 = GND, 3 = VS Remote control Leaded
Datasheet
Minimold 5.4 W x 6.35 H x 4.9 D 30 AGC5 45 0.12 45 0.7 1 = OUT, 2 = GND, 3 = VS Remote control Leaded
Datasheet
Minimold 5.4 W x 6.35 H x 4.9 D 33 AGC5 45 0.08 45 0.35 1 = OUT, 2 = GND, 3 = VS Remote control Leaded
Datasheet
Minimold 5.4 W x 6.35 H x 4.9 D 33 AGC5 45 0.12 45 0.7 1 = OUT, 2 = GND, 3 = VS Remote control Leaded
Datasheet
Minimold 5.4 W x 6.35 H x 4.9 D 36 AGC5 45 0.08 45 0.35 1 = OUT, 2 = GND, 3 = VS Remote control Leaded
Datasheet
Minimold 5.4 W x 6.35 H x 4.9 D 36 AGC5 45 0.12 45 0.7 1 = OUT, 2 = GND, 3 = VS Remote control Leaded
Datasheet
Minimold 5.4 W x 6.35 H x 4.9 D 38 AGC5 45 0.08 45 0.35 1 = OUT, 2 = GND, 3 = VS Remote control Leaded
Datasheet
Minimold 5.4 W x 6.35 H x 4.9 D 38 AGC5 45 0.12 45 0.7 1 = OUT, 2 = GND, 3 = VS Remote control Leaded
Datasheet
Minimold 5.4 W x 6.35 H x 4.9 D 40 AGC5 45 0.08 45 0.35 1 = OUT, 2 = GND, 3 = VS Remote control Leaded
Datasheet
Minimold 5.4 W x 6.35 H x 4.9 D 40 AGC5 45 0.12 45 0.7 1 = OUT, 2 = GND, 3 = VS Remote control Leaded
Datasheet
Minimold 5.4 W x 6.35 H x 4.9 D 56 AGC5 45 0.08 45 0.35 1 = OUT, 2 = GND, 3 = VS Remote control Leaded
Datasheet
Minimold 5.4 W x 6.35 H x 4.9 D 56 AGC5 45 0.12 45 0.7 1 = OUT, 2 = GND, 3 = VS Remote control Leaded