IR receiver modules - Mold
Part number
Product Image
Package
Dimensions
(mm)
Carrier Frequency
(kHz)
AGC
Type
Transmission Distance Typ.
(m)
Detection Threshold / Sensitivity Typ.
Viewing Angle
()
Supply Current Typ.
Pinning
Remote Control Code
Application
Mounting
Datasheet
Mold 6.0 W x 6.95 H x 5.6 D 38 Repeater 20 0.6 45 0.7 1 = carrier OUT, 2 = GND, 3 = VS Repeater Leaded
Datasheet
Mold 6.0 W x 6.95 H x 5.6 D 38 25 0.4 45 0.7 1 = OUT, 2 = GND, 3 = VS Presence sensors, fast proximity sensors Leaded
Datasheet
Mold 6.0 W x 6.95 H x 5.6 D 38 7 7 45 0.7 1 = OUT, 2 = GND, 3 = VS Presence sensors Leaded
Datasheet
Mold 6.0 W x 6.95 H x 5.6 D 38 45 0.12 45 0.7 1 = OUT, 2 = GND, 3 = VS Proximity sensors Leaded
Datasheet
Mold 6.0 W x 6.95 H x 5.6 D 56 25 0.4 45 0.7 1 = OUT, 2 = GND, 3 = VS Presence sensors, fast proximity sensors Leaded
Datasheet
Mold 6.0 W x 6.95 H x 5.6 D 56 7 7 45 0.7 1 = OUT, 2 = GND, 3 = VS Presence sensors Leaded
Datasheet
Mold 6.0 W x 6.95 H x 5.6 D 40 AGC-S 45 0.08 45 0.35 1 = OUT, 2 = VS, 3 = GND Sony 12 15 and 20 bit IR-codes Leaded
Datasheet
Mold 6.0 W x 6.95 H x 5.6 D 40 AGC-S 45 0.08 45 0.35 1 = OUT, 2 = GND, 3 = VS Sony 12 15 and 20 bit IR-codes Leaded
Datasheet
Mold 6.0 W x 6.95 H x 5.6 D 30 AGC1 30 0.08 45 0.70 1 = OUT, 2 = VS, 3 = GND RECS-80 Code Remote control Leaded
Datasheet
Mold 6.0 W x 6.95 H x 5.6 D 30 AGC1 30 0.08 45 0.70 1 = OUT, 2 = GND, 3 = VS RCMM Remote control Leaded
Datasheet
Mold 6.0 W x 6.95 H x 5.6 D 30 AGC1 45 0.12 45 0.7 1 = OUT, 2 = VS, 3 = GND Mitsubishi Remote control Leaded
Datasheet
Mold 6.0 W x 6.95 H x 5.6 D 30 AGC1 45 0.08 45 0.35 1 = OUT, 2 = VS, 3 = GND Mitsubishi Remote control Leaded
Datasheet
Mold 6.0 W x 6.95 H x 5.6 D 30 AGC1 45 0.08 45 0.35 1 = OUT, 2 = GND, 3 = VS MCIR Remote control Leaded
Datasheet
Mold 6.0 W x 6.95 H x 5.6 D 30 AGC1 45 0.12 45 0.7 1 = OUT, 2 = GND, 3 = VS MCIR Remote control Leaded
Datasheet
Mold 6.0 W x 6.95 H x 5.6 D 33 AGC1 30 0.08 45 0.70 1 = OUT, 2 = VS, 3 = GND RECS-80 Code Remote control Leaded
Datasheet
Mold 6.0 W x 6.95 H x 5.6 D 33 AGC1 30 0.08 45 0.70 1 = OUT, 2 = GND, 3 = VS RCMM Remote control Leaded
Datasheet
Mold 6.0 W x 6.95 H x 5.6 D 33 AGC1 45 0.12 45 0.7 1 = OUT, 2 = VS, 3 = GND Mitsubishi Remote control Leaded
Datasheet
Mold 6.0 W x 6.95 H x 5.6 D 33 AGC1 45 0.08 45 0.35 1 = OUT, 2 = VS, 3 = GND Mitsubishi Remote control Leaded
Datasheet
Mold 6.0 W x 6.95 H x 5.6 D 33 AGC1 45 0.08 45 0.35 1 = OUT, 2 = GND, 3 = VS MCIR Remote control Leaded
Datasheet
Mold 6.0 W x 6.95 H x 5.6 D 33 AGC1 45 0.12 45 0.7 1 = OUT, 2 = GND, 3 = VS MCIR Remote control Leaded
Datasheet
Mold 6.0 W x 6.95 H x 5.6 D 36 AGC1 30 0.08 45 0.70 1 = OUT, 2 = VS, 3 = GND RECS-80 Code Remote control Leaded
Datasheet
Mold 6.0 W x 6.95 H x 5.6 D 36 AGC1 30 0.08 45 0.70 1 = OUT, 2 = GND, 3 = VS RCMM Remote control Leaded
Datasheet
Mold 6.0 W x 6.95 H x 5.6 D 36 AGC1 45 0.12 45 0.7 1 = OUT, 2 = VS, 3 = GND Mitsubishi Remote control Leaded
Datasheet
Mold 6.0 W x 6.95 H x 5.6 D 36 AGC1 45 0.08 45 0.35 1 = OUT, 2 = VS, 3 = GND Mitsubishi Remote control Leaded
Datasheet
Mold 6.0 W x 6.95 H x 5.6 D 36 AGC1 45 0.08 45 0.35 1 = OUT, 2 = GND, 3 = VS MCIR Remote control Leaded
Datasheet
Mold 6.0 W x 6.95 H x 5.6 D 36 AGC1 45 0.12 45 0.7 1 = OUT, 2 = GND, 3 = VS MCIR Remote control Leaded
Datasheet
Mold 6.0 W x 6.95 H x 5.6 D 38 AGC1 30 0.08 45 0.70 1 = OUT, 2 = VS, 3 = GND RECS-80 Code Remote control Leaded
Datasheet
Mold 6.0 W x 6.95 H x 5.6 D 38 AGC1 30 0.08 45 0.70 1 = OUT, 2 = GND, 3 = VS RCMM Remote control Leaded
Datasheet
Mold 6.0 W x 6.95 H x 5.6 D 38 AGC1 45 0.12 45 0.7 1 = OUT, 2 = VS, 3 = GND Mitsubishi Remote control Leaded
Datasheet
Mold 6.0 W x 6.95 H x 5.6 D 38 AGC1 45 0.08 45 0.35 1 = OUT, 2 = VS, 3 = GND Mitsubishi Remote control Leaded
Datasheet
Mold 6.0 W x 6.95 H x 5.6 D 38 AGC1 45 0.08 45 0.35 1 = OUT, 2 = GND, 3 = VS MCIR Remote control Leaded
Datasheet
Mold 6.0 W x 6.95 H x 5.6 D 38 AGC1 45 0.12 45 0.7 1 = OUT, 2 = GND, 3 = VS MCIR Remote control Leaded
Datasheet
Mold 6.0 W x 6.95 H x 5.6 D 38.4 AGC1 35 0.15 45 0.35 1 = OUT, 2 = GND, 3 = VS Data transmission Leaded
Datasheet
Mold 6.0 W x 6.95 H x 5.6 D 40 AGC1 30 0.08 45 0.70 1 = OUT, 2 = VS, 3 = GND RECS-80 Code Remote control Leaded
Datasheet
Mold 6.0 W x 6.95 H x 5.6 D 40 AGC1 30 0.08 45 0.70 1 = OUT, 2 = GND, 3 = VS RCMM Remote control Leaded
Datasheet
Mold 6.0 W x 6.95 H x 5.6 D 40 AGC1 45 0.12 45 0.7 1 = OUT, 2 = VS, 3 = GND Mitsubishi Remote control Leaded
Datasheet
Mold 6.0 W x 6.95 H x 5.6 D 40 AGC1 45 0.08 45 0.35 1 = OUT, 2 = VS, 3 = GND Mitsubishi Remote control Leaded
Datasheet
Mold 6.0 W x 6.95 H x 5.6 D 40 AGC1 45 0.08 45 0.35 1 = OUT, 2 = GND, 3 = VS MCIR Remote control Leaded
Datasheet
Mold 6.0 W x 6.95 H x 5.6 D 40 AGC1 45 0.12 45 0.7 1 = OUT, 2 = GND, 3 = VS MCIR Remote control Leaded
Datasheet
Mold 6.0 W x 6.95 H x 5.6 D 56 AGC1 30 0.08 45 0.70 1 = OUT, 2 = VS, 3 = GND RECS-80 Code Remote control Leaded
Datasheet
Mold 6.0 W x 6.95 H x 5.6 D 56 AGC1 30 0.08 45 0.70 1 = OUT, 2 = GND, 3 = VS RCMM Remote control Leaded
Datasheet
Mold 6.0 W x 6.95 H x 5.6 D 56 AGC1 45 0.12 45 0.7 1 = OUT, 2 = VS, 3 = GND Mitsubishi Remote control Leaded
Datasheet
Mold 6.0 W x 6.95 H x 5.6 D 56 AGC1 45 0.08 45 0.35 1 = OUT, 2 = VS, 3 = GND Mitsubishi Remote control Leaded
Datasheet
Mold 6.0 W x 6.95 H x 5.6 D 56 AGC1 45 0.08 45 0.35 1 = OUT, 2 = GND, 3 = VS MCIR Remote control Leaded
Datasheet
Mold 6.0 W x 6.95 H x 5.6 D 56 AGC1 45 0.12 45 0.7 1 = OUT, 2 = GND, 3 = VS MCIR Remote control Leaded
Datasheet
Mold 6.0 W x 6.95 H x 5.6 D 57.6 AGC1 35 0.15 45 0.35 1 = OUT, 2 = GND, 3 = VS Data transmission Leaded
Datasheet
Mold 6.0 W x 6.95 H x 5.6 D 30 AGC2 30 0.08 45 0.70 1 = OUT, 2 = VS, 3 = GND MCIR Remote control Leaded
Datasheet
Mold 6.0 W x 6.95 H x 5.6 D 30 AGC2 30 0.08 45 0.70 1 = OUT, 2 = GND, 3 = VS Cisco Remote control Leaded
Datasheet
Mold 6.0 W x 6.95 H x 5.6 D 30 AGC2 45 0.12 45 0.7 1 = OUT, 2 = VS, 3 = GND RC-6 Remote control Leaded
Datasheet
Mold 6.0 W x 6.95 H x 5.6 D 30 AGC2 45 0.08 45 0.35 1 = OUT, 2 = VS, 3 = GND RC-6 Remote control Leaded
Datasheet
Mold 6.0 W x 6.95 H x 5.6 D 30 AGC2 45 0.08 45 0.35 1 = OUT, 2 = GND, 3 = VS RC-5 Remote control Leaded
Datasheet
Mold 6.0 W x 6.95 H x 5.6 D 30 AGC2 45 0.12 45 0.7 1 = OUT, 2 = GND, 3 = VS RC-5 Remote control Leaded
Datasheet
Mold 6.0 W x 6.95 H x 5.6 D 33 AGC2 30 0.08 45 0.70 1 = OUT, 2 = VS, 3 = GND MCIR Remote control Leaded
Datasheet
Mold 6.0 W x 6.95 H x 5.6 D 33 AGC2 30 0.08 45 0.70 1 = OUT, 2 = GND, 3 = VS Cisco Remote control Leaded
Datasheet
Mold 6.0 W x 6.95 H x 5.6 D 33 AGC2 45 0.12 45 0.7 1 = OUT, 2 = VS, 3 = GND RC-6 Remote control Leaded
Datasheet
Mold 6.0 W x 6.95 H x 5.6 D 33 AGC2 45 0.08 45 0.35 1 = OUT, 2 = VS, 3 = GND RC-6 Remote control Leaded
Datasheet
Mold 6.0 W x 6.95 H x 5.6 D 33 AGC2 45 0.08 45 0.35 1 = OUT, 2 = GND, 3 = VS RC-5 Remote control Leaded
Datasheet
Mold 6.0 W x 6.95 H x 5.6 D 33 AGC2 45 0.12 45 0.7 1 = OUT, 2 = GND, 3 = VS RC-5 Remote control Leaded
Datasheet
Mold 6.0 W x 6.95 H x 5.6 D 36 AGC2 30 0.08 45 0.70 1 = OUT, 2 = VS, 3 = GND MCIR Remote control Leaded
Datasheet
Mold 6.0 W x 6.95 H x 5.6 D 36 AGC2 30 0.08 45 0.70 1 = OUT, 2 = GND, 3 = VS Cisco Remote control Leaded
Datasheet
Mold 6.0 W x 6.95 H x 5.6 D 36 AGC2 45 0.12 45 0.7 1 = OUT, 2 = VS, 3 = GND RC-6 Remote control Leaded
Datasheet
Mold 6.0 W x 6.95 H x 5.6 D 36 AGC2 45 0.08 45 0.35 1 = OUT, 2 = VS, 3 = GND RC-6 Remote control Leaded
Datasheet
Mold 6.0 W x 6.95 H x 5.6 D 36 AGC2 45 0.08 45 0.35 1 = OUT, 2 = GND, 3 = VS RC-5 Remote control Leaded
Datasheet
Mold 6.0 W x 6.95 H x 5.6 D 36 AGC2 45 0.12 45 0.7 1 = OUT, 2 = GND, 3 = VS RC-5 Remote control Leaded
Datasheet
Mold 6.0 W x 6.95 H x 5.6 D 38 AGC2 30 0.08 45 0.70 1 = OUT, 2 = VS, 3 = GND MCIR Remote control Leaded
Datasheet
Mold 6.0 W x 6.95 H x 5.6 D 38 AGC2 30 0.08 45 0.70 1 = OUT, 2 = GND, 3 = VS Cisco Remote control Leaded
Datasheet
Mold 6.0 W x 6.95 H x 5.6 D 38 AGC2 45 0.12 45 0.7 1 = OUT, 2 = VS, 3 = GND RC-6 Remote control Leaded
Datasheet
Mold 6.0 W x 6.95 H x 5.6 D 38 AGC2 45 0.08 45 0.35 1 = OUT, 2 = VS, 3 = GND RC-6 Remote control Leaded
Datasheet
Mold 6.0 W x 6.95 H x 5.6 D 38 AGC2 45 0.08 45 0.35 1 = OUT, 2 = GND, 3 = VS RC-5 Remote control Leaded
Datasheet
Mold 6.0 W x 6.95 H x 5.6 D 38 AGC2 45 0.12 45 0.7 1 = OUT, 2 = GND, 3 = VS RC-5 Remote control Leaded
Datasheet
Mold 6.0 W x 6.95 H x 5.6 D 40 AGC2 30 0.08 45 0.70 1 = OUT, 2 = VS, 3 = GND Sony Remote control Leaded
Datasheet
Mold 6.0 W x 6.95 H x 5.6 D 40 AGC2 30 0.08 45 0.70 1 = OUT, 2 = GND, 3 = VS Sony Remote control Leaded
Datasheet
Mold 6.0 W x 6.95 H x 5.6 D 40 AGC2 45 0.12 45 0.7 1 = OUT, 2 = VS, 3 = GND RC-6 Remote control Leaded
Datasheet
Mold 6.0 W x 6.95 H x 5.6 D 40 AGC2 45 0.08 45 0.35 1 = OUT, 2 = VS, 3 = GND RC-6 Remote control Leaded
Datasheet
Mold 6.0 W x 6.95 H x 5.6 D 40 AGC2 45 0.08 45 0.35 1 = OUT, 2 = GND, 3 = VS RC-5 Remote control Leaded
Datasheet
Mold 6.0 W x 6.95 H x 5.6 D 40 AGC2 45 0.12 45 0.7 1 = OUT, 2 = GND, 3 = VS RC-5 Remote control Leaded
Datasheet
Mold 6.0 W x 6.95 H x 5.6 D 56 AGC2 30 0.08 45 0.70 1 = OUT, 2 = VS, 3 = GND Cisco Remote control Leaded
Datasheet
Mold 6.0 W x 6.95 H x 5.6 D 56 AGC2 30 0.08 45 0.70 1 = OUT, 2 = GND, 3 = VS Cisco Remote control Leaded
Datasheet
Mold 6.0 W x 6.95 H x 5.6 D 56 AGC2 45 0.12 45 0.7 1 = OUT, 2 = VS, 3 = GND RC-6 Remote control Leaded
Datasheet
Mold 6.0 W x 6.95 H x 5.6 D 56 AGC2 45 0.08 45 0.35 1 = OUT, 2 = VS, 3 = GND RC-6 Remote control Leaded
Datasheet
Mold 6.0 W x 6.95 H x 5.6 D 56 AGC2 45 0.08 45 0.35 1 = OUT, 2 = GND, 3 = VS RC-5 Remote control Leaded
Datasheet
Mold 6.0 W x 6.95 H x 5.6 D 56 AGC2 45 0.12 45 0.7 1 = OUT, 2 = GND, 3 = VS RC-5 Remote control Leaded
Datasheet
Mold 6.0 W x 6.95 H x 5.6 D 30 AGC3 30 0.08 45 0.70 1 = OUT, 2 = VS, 3 = GND XMP-1, XMP-2 Remote control Leaded
Datasheet
Mold 6.0 W x 6.95 H x 5.6 D 30 AGC3 30 0.08 45 0.70 1 = OUT, 2 = GND, 3 = VS r-map Remote control Leaded
Datasheet
Mold 6.0 W x 6.95 H x 5.6 D 30 AGC3 45 0.12 45 0.7 1 = OUT, 2 = VS, 3 = GND r-map Remote control Leaded
Datasheet
Mold 6.0 W x 6.95 H x 5.6 D 30 AGC3 45 0.08 45 0.35 1 = OUT, 2 = VS, 3 = GND r-map Remote control Leaded
Datasheet
Mold 6.0 W x 6.95 H x 5.6 D 30 AGC3 45 0.08 45 0.35 1 = OUT, 2 = GND, 3 = VS RECS-80 Code Remote control Leaded
Datasheet
Mold 6.0 W x 6.95 H x 5.6 D 30 AGC3 45 0.12 45 0.7 1 = OUT, 2 = GND, 3 = VS RECS-80 Code Remote control Leaded
Datasheet
Mold 6.0 W x 6.95 H x 5.6 D 33 AGC3 30 0.08 45 0.70 1 = OUT, 2 = VS, 3 = GND XMP-1, XMP-2 Remote control Leaded
Datasheet
Mold 6.0 W x 6.95 H x 5.6 D 33 AGC3 30 0.08 45 0.70 1 = OUT, 2 = GND, 3 = VS r-map Remote control Leaded
Datasheet
Mold 6.0 W x 6.95 H x 5.6 D 33 AGC3 45 0.12 45 0.7 1 = OUT, 2 = VS, 3 = GND r-map Remote control Leaded
Datasheet
Mold 6.0 W x 6.95 H x 5.6 D 33 AGC3 45 0.08 45 0.35 1 = OUT, 2 = VS, 3 = GND r-map Remote control Leaded
Datasheet
Mold 6.0 W x 6.95 H x 5.6 D 33 AGC3 45 0.08 45 0.35 1 = OUT, 2 = GND, 3 = VS RECS-80 Code Remote control Leaded
Datasheet
Mold 6.0 W x 6.95 H x 5.6 D 33 AGC3 45 0.12 45 0.7 1 = OUT, 2 = GND, 3 = VS RECS-80 Code Remote control Leaded
Datasheet
Mold 6.0 W x 6.95 H x 5.6 D 36 AGC3 30 0.08 45 0.70 1 = OUT, 2 = VS, 3 = GND RCMM Remote control Leaded
Datasheet
Mold 6.0 W x 6.95 H x 5.6 D 36 AGC3 30 0.08 45 0.70 1 = OUT, 2 = GND, 3 = VS RCMM Remote control Leaded
Datasheet
Mold 6.0 W x 6.95 H x 5.6 D 36 AGC3 45 0.12 45 0.7 1 = OUT, 2 = VS, 3 = GND MCIR Remote control Leaded
Datasheet
Mold 6.0 W x 6.95 H x 5.6 D 36 AGC3 45 0.08 45 0.35 1 = OUT, 2 = VS, 3 = GND Remote control Leaded
Datasheet
Mold 6.0 W x 6.95 H x 5.6 D 36 AGC3 45 0.08 45 0.35 1 = OUT, 2 = GND, 3 = VS Remote control Leaded
Datasheet
Mold 6.0 W x 6.95 H x 5.6 D 36 AGC3 45 0.12 45 0.7 1 = OUT, 2 = GND, 3 = VS MCIR Remote control Leaded
Datasheet
Mold 6.0 W x 6.95 H x 5.6 D 38 AGC3 30 0.08 45 0.70 1 = OUT, 2 = VS, 3 = GND Remote control Leaded
Datasheet
Mold 6.0 W x 6.95 H x 5.6 D 38 AGC3 30 0.08 45 0.70 1 = OUT, 2 = GND, 3 = VS Remote control Leaded
Datasheet
Mold 6.0 W x 6.95 H x 5.6 D 38 AGC3 45 0.12 45 0.7 1 = OUT, 2 = VS, 3 = GND Remote control Leaded
Datasheet
Mold 6.0 W x 6.95 H x 5.6 D 38 AGC3 45 0.08 45 0.35 1 = OUT, 2 = VS, 3 = GND Remote control Leaded
Datasheet
Mold 6.0 W x 6.95 H x 5.6 D 38 AGC3 45 0.08 45 0.35 1 = OUT, 2 = GND, 3 = VS Remote control Leaded
Datasheet
Mold 6.0 W x 6.95 H x 5.6 D 38 AGC3 45 0.12 45 0.7 1 = OUT, 2 = GND, 3 = VS Remote control Leaded
Datasheet
Mold 6.0 W x 6.95 H x 5.6 D 38.4 AGC3 35 0.15 45 0.35 1 = OUT, 2 = GND, 3 = VS Data transmission Leaded
Datasheet
Mold 6.0 W x 6.95 H x 5.6 D 40 AGC3 30 0.08 45 0.70 1 = OUT, 2 = VS, 3 = GND XMP-1, XMP-2 Remote control Leaded
Datasheet
Mold 6.0 W x 6.95 H x 5.6 D 40 AGC3 30 0.08 45 0.70 1 = OUT, 2 = GND, 3 = VS r-map Remote control Leaded
Datasheet
Mold 6.0 W x 6.95 H x 5.6 D 40 AGC3 45 0.12 45 0.7 1 = OUT, 2 = VS, 3 = GND r-map Remote control Leaded
Datasheet
Mold 6.0 W x 6.95 H x 5.6 D 40 AGC3 45 0.08 45 0.35 1 = OUT, 2 = VS, 3 = GND r-map Remote control Leaded
Datasheet
Mold 6.0 W x 6.95 H x 5.6 D 40 AGC3 45 0.08 45 0.35 1 = OUT, 2 = GND, 3 = VS RECS-80 Code Remote control Leaded
Datasheet
Mold 6.0 W x 6.95 H x 5.6 D 40 AGC3 45 0.12 45 0.7 1 = OUT, 2 = GND, 3 = VS RECS-80 Code Remote control Leaded
Datasheet
Mold 6.0 W x 6.95 H x 5.6 D 56 AGC3 30 0.08 45 0.70 1 = OUT, 2 = VS, 3 = GND r-map Remote control Leaded
Datasheet
Mold 6.0 W x 6.95 H x 5.6 D 56 AGC3 30 0.08 45 0.70 1 = OUT, 2 = GND, 3 = VS r-map Remote control Leaded
Datasheet
Mold 6.0 W x 6.95 H x 5.6 D 56 AGC3 45 0.12 45 0.7 1 = OUT, 2 = VS, 3 = GND r-map Remote control Leaded
Datasheet
Mold 6.0 W x 6.95 H x 5.6 D 56 AGC3 45 0.08 45 0.35 1 = OUT, 2 = VS, 3 = GND r-map Remote control Leaded
Datasheet
Mold 6.0 W x 6.95 H x 5.6 D 56 AGC3 45 0.08 45 0.35 1 = OUT, 2 = GND, 3 = VS RECS-80 Code Remote control Leaded
Datasheet
Mold 6.0 W x 6.95 H x 5.6 D 56 AGC3 45 0.12 45 0.7 1 = OUT, 2 = GND, 3 = VS RECS-80 Code Remote control Leaded
Datasheet
Mold 6.0 W x 6.95 H x 5.6 D 57.6 AGC3 35 0.15 45 0.35 1 = OUT, 2 = GND, 3 = VS Data transmission Leaded
Datasheet
Mold 6.0 W x 6.95 H x 5.6 D 30 AGC4 30 0.08 45 0.70 1 = OUT, 2 = VS, 3 = GND NEC Remote control Leaded
Datasheet
Mold 6.0 W x 6.95 H x 5.6 D 30 AGC4 30 0.08 45 0.70 1 = OUT, 2 = GND, 3 = VS Mitsubishi Remote control Leaded
Datasheet
Mold 6.0 W x 6.95 H x 5.6 D 30 AGC4 45 0.12 45 0.7 1 = OUT, 2 = VS, 3 = GND NEC Remote control Leaded
Datasheet
Mold 6.0 W x 6.95 H x 5.6 D 30 AGC4 45 0.08 45 0.35 1 = OUT, 2 = VS, 3 = GND NEC Remote control Leaded
Datasheet
Mold 6.0 W x 6.95 H x 5.6 D 30 AGC4 45 0.08 45 0.35 1 = OUT, 2 = GND, 3 = VS Panasonic Remote control Leaded
Datasheet
Mold 6.0 W x 6.95 H x 5.6 D 30 AGC4 45 0.12 45 0.7 1 = OUT, 2 = GND, 3 = VS Panasonic Remote control Leaded
Datasheet
Mold 6.0 W x 6.95 H x 5.6 D 33 AGC4 30 0.08 45 0.70 1 = OUT, 2 = VS, 3 = GND NEC Remote control Leaded
Datasheet
Mold 6.0 W x 6.95 H x 5.6 D 33 AGC4 30 0.08 45 0.70 1 = OUT, 2 = GND, 3 = VS Mitsubishi Remote control Leaded
Datasheet
Mold 6.0 W x 6.95 H x 5.6 D 33 AGC4 45 0.12 45 0.7 1 = OUT, 2 = VS, 3 = GND NEC Remote control Leaded
Datasheet
Mold 6.0 W x 6.95 H x 5.6 D 33 AGC4 45 0.08 45 0.35 1 = OUT, 2 = VS, 3 = GND NEC Remote control Leaded
Datasheet
Mold 6.0 W x 6.95 H x 5.6 D 33 AGC4 45 0.08 45 0.35 1 = OUT, 2 = GND, 3 = VS Panasonic Remote control Leaded
Datasheet
Mold 6.0 W x 6.95 H x 5.6 D 33 AGC4 45 0.12 45 0.7 1 = OUT, 2 = GND, 3 = VS Panasonic Remote control Leaded
Datasheet
Mold 6.0 W x 6.95 H x 5.6 D 36 AGC4 30 0.08 45 0.70 1 = OUT, 2 = VS, 3 = GND Remote control Leaded
Datasheet
Mold 6.0 W x 6.95 H x 5.6 D 36 AGC4 30 0.08 45 0.70 1 = OUT, 2 = GND, 3 = VS Remote control Leaded
Datasheet
Mold 6.0 W x 6.95 H x 5.6 D 36 AGC4 45 0.12 45 0.7 1 = OUT, 2 = VS, 3 = GND Remote control Leaded
Datasheet
Mold 6.0 W x 6.95 H x 5.6 D 36 AGC4 45 0.08 45 0.35 1 = OUT, 2 = VS, 3 = GND Remote control Leaded
Datasheet
Mold 6.0 W x 6.95 H x 5.6 D 36 AGC4 45 0.08 45 0.35 1 = OUT, 2 = GND, 3 = VS Remote control Leaded
Datasheet
Mold 6.0 W x 6.95 H x 5.6 D 36 AGC4 45 0.12 45 0.7 1 = OUT, 2 = GND, 3 = VS Remote control Leaded
Datasheet
Mold 6.0 W x 6.95 H x 5.6 D 38 AGC4 30 0.08 45 0.70 1 = OUT, 2 = VS, 3 = GND Remote control Leaded
Datasheet
Mold 6.0 W x 6.95 H x 5.6 D 38 AGC4 30 0.08 45 0.70 1 = OUT, 2 = GND, 3 = VS Remote control Leaded
Datasheet
Mold 6.0 W x 6.95 H x 5.6 D 38 AGC4 45 0.12 45 0.7 1 = OUT, 2 = VS, 3 = GND Remote control Leaded
Datasheet
Mold 6.0 W x 6.95 H x 5.6 D 38 AGC4 45 0.08 45 0.35 1 = OUT, 2 = VS, 3 = GND Remote control Leaded
Datasheet
Mold 6.0 W x 6.95 H x 5.6 D 38 AGC4 45 0.08 45 0.35 1 = OUT, 2 = GND, 3 = VS Remote control Leaded
Datasheet
Mold 6.0 W x 6.95 H x 5.6 D 38 AGC4 45 0.12 45 0.7 1 = OUT, 2 = GND, 3 = VS Remote control Leaded
Datasheet
Mold 6.0 W x 6.95 H x 5.6 D 40 AGC4 30 0.08 45 0.70 1 = OUT, 2 = VS, 3 = GND NEC Remote control Leaded
Datasheet
Mold 6.0 W x 6.95 H x 5.6 D 40 AGC4 30 0.08 45 0.70 1 = OUT, 2 = GND, 3 = VS Mitsubishi Remote control Leaded
Datasheet
Mold 6.0 W x 6.95 H x 5.6 D 40 AGC4 45 0.12 45 0.7 1 = OUT, 2 = VS, 3 = GND NEC Remote control Leaded
Datasheet
Mold 6.0 W x 6.95 H x 5.6 D 40 AGC4 45 0.08 45 0.35 1 = OUT, 2 = VS, 3 = GND NEC Remote control Leaded
Datasheet
Mold 6.0 W x 6.95 H x 5.6 D 40 AGC4 45 0.08 45 0.35 1 = OUT, 2 = GND, 3 = VS Panasonic Remote control Leaded
Datasheet
Mold 6.0 W x 6.95 H x 5.6 D 40 AGC4 45 0.12 45 0.7 1 = OUT, 2 = GND, 3 = VS Panasonic Remote control Leaded
Datasheet
Mold 6.0 W x 6.95 H x 5.6 D 56 AGC4 30 0.08 45 0.70 1 = OUT, 2 = VS, 3 = GND r-step Remote control Leaded
Datasheet
Mold 6.0 W x 6.95 H x 5.6 D 56 AGC4 30 0.08 45 0.70 1 = OUT, 2 = GND, 3 = VS r-step Remote control Leaded
Datasheet
Mold 6.0 W x 6.95 H x 5.6 D 56 AGC4 45 0.12 45 0.7 1 = OUT, 2 = VS, 3 = GND Remote control Leaded
Datasheet
Mold 6.0 W x 6.95 H x 5.6 D 56 AGC4 45 0.08 45 0.35 1 = OUT, 2 = VS, 3 = GND Remote control Leaded
Datasheet
Mold 6.0 W x 6.95 H x 5.6 D 56 AGC4 45 0.08 45 0.35 1 = OUT, 2 = GND, 3 = VS Remote control Leaded
Datasheet
Mold 6.0 W x 6.95 H x 5.6 D 56 AGC4 45 0.12 45 0.7 1 = OUT, 2 = GND, 3 = VS Remote control Leaded
Datasheet
Mold 6.0 W x 6.95 H x 5.6 D 30 AGC5 30 0.08 45 0.70 1 = OUT, 2 = VS, 3 = GND Remote control Leaded
Datasheet
Mold 6.0 W x 6.95 H x 5.6 D 30 AGC5 30 0.08 45 0.70 1 = OUT, 2 = GND, 3 = VS Remote control Leaded
Datasheet
Mold 6.0 W x 6.95 H x 5.6 D 30 AGC5 45 0.12 45 0.7 1 = OUT, 2 = VS, 3 = GND Remote control Leaded
Datasheet
Mold 6.0 W x 6.95 H x 5.6 D 30 AGC5 45 0.08 45 0.35 1 = OUT, 2 = VS, 3 = GND RCMM Remote control Leaded
Datasheet
Mold 6.0 W x 6.95 H x 5.6 D 30 AGC5 45 0.08 45 0.35 1 = OUT, 2 = GND, 3 = VS XMP-1, XMP-2 Remote control Leaded
Datasheet
Mold 6.0 W x 6.95 H x 5.6 D 30 AGC5 45 0.12 45 0.7 1 = OUT, 2 = GND, 3 = VS XMP-1, XMP-2 Remote control Leaded
Datasheet
Mold 6.0 W x 6.95 H x 5.6 D 33 AGC5 30 0.08 45 0.70 1 = OUT, 2 = VS, 3 = GND Remote control Leaded
Datasheet
Mold 6.0 W x 6.95 H x 5.6 D 33 AGC5 30 0.08 45 0.70 1 = OUT, 2 = GND, 3 = VS Remote control Leaded
Datasheet
Mold 6.0 W x 6.95 H x 5.6 D 33 AGC5 45 0.12 45 0.7 1 = OUT, 2 = VS, 3 = GND Remote control Leaded
Datasheet
Mold 6.0 W x 6.95 H x 5.6 D 33 AGC5 45 0.08 45 0.35 1 = OUT, 2 = VS, 3 = GND RCMM Remote control Leaded
Datasheet
Mold 6.0 W x 6.95 H x 5.6 D 33 AGC5 45 0.08 45 0.35 1 = OUT, 2 = GND, 3 = VS XMP-1, XMP-2 Remote control Leaded
Datasheet
Mold 6.0 W x 6.95 H x 5.6 D 33 AGC5 45 0.12 45 0.7 1 = OUT, 2 = GND, 3 = VS XMP-1, XMP-2 Remote control Leaded
Datasheet
Mold 6.0 W x 6.95 H x 5.6 D 36 AGC5 30 0.08 45 0.70 1 = OUT, 2 = VS, 3 = GND Remote control Leaded
Datasheet
Mold 6.0 W x 6.95 H x 5.6 D 36 AGC5 30 0.08 45 0.70 1 = OUT, 2 = GND, 3 = VS Remote control Leaded
Datasheet
Mold 6.0 W x 6.95 H x 5.6 D 36 AGC5 45 0.12 45 0.7 1 = OUT, 2 = VS, 3 = GND MCIR Remote control Leaded
Datasheet
Mold 6.0 W x 6.95 H x 5.6 D 36 AGC5 45 0.08 45 0.35 1 = OUT, 2 = VS, 3 = GND RCMM Remote control Leaded
Datasheet
Mold 6.0 W x 6.95 H x 5.6 D 36 AGC5 45 0.08 45 0.35 1 = OUT, 2 = GND, 3 = VS XMP-1, XMP-2 Remote control Leaded
Datasheet
Mold 6.0 W x 6.95 H x 5.6 D 36 AGC5 45 0.12 45 0.7 1 = OUT, 2 = GND, 3 = VS XMP-1, XMP-2 Remote control Leaded
Datasheet
Mold 6.0 W x 6.95 H x 5.6 D 38 AGC5 30 0.08 45 0.70 1 = OUT, 2 = VS, 3 = GND Remote control Leaded
Datasheet
Mold 6.0 W x 6.95 H x 5.6 D 38 AGC5 30 0.08 45 0.70 1 = OUT, 2 = GND, 3 = VS Remote control Leaded
Datasheet
Mold 6.0 W x 6.95 H x 5.6 D 38 AGC5 45 0.12 45 0.7 1 = OUT, 2 = VS, 3 = GND Remote control Leaded
Datasheet
Mold 6.0 W x 6.95 H x 5.6 D 38 AGC5 45 0.08 45 0.35 1 = OUT, 2 = VS, 3 = GND RCMM Remote control Leaded
Datasheet
Mold 6.0 W x 6.95 H x 5.6 D 38 AGC5 45 0.08 45 0.35 1 = OUT, 2 = GND, 3 = VS XMP-1, XMP-2 Remote control Leaded
Datasheet
Mold 6.0 W x 6.95 H x 5.6 D 38 AGC5 45 0.12 45 0.7 1 = OUT, 2 = GND, 3 = VS XMP-1, XMP-2 Remote control Leaded
Datasheet
Mold 6.0 W x 6.95 H x 5.6 D 40 AGC5 30 0.08 45 0.70 1 = OUT, 2 = VS, 3 = GND Remote control Leaded
Datasheet
Mold 6.0 W x 6.95 H x 5.6 D 40 AGC5 30 0.08 45 0.70 1 = OUT, 2 = GND, 3 = VS Remote control Leaded
Datasheet
Mold 6.0 W x 6.95 H x 5.6 D 40 AGC5 45 0.12 45 0.7 1 = OUT, 2 = VS, 3 = GND Remote control Leaded
Datasheet
Mold 6.0 W x 6.95 H x 5.6 D 40 AGC5 45 0.08 45 0.35 1 = OUT, 2 = VS, 3 = GND RCMM Remote control Leaded
Datasheet
Mold 6.0 W x 6.95 H x 5.6 D 40 AGC5 45 0.08 45 0.35 1 = OUT, 2 = GND, 3 = VS XMP-1, XMP-2 Remote control Leaded
Datasheet
Mold 6.0 W x 6.95 H x 5.6 D 40 AGC5 45 0.12 45 0.7 1 = OUT, 2 = GND, 3 = VS XMP-1, XMP-2 Remote control Leaded
Datasheet
Mold 6.0 W x 6.95 H x 5.6 D 56 AGC5 30 0.08 45 0.70 1 = OUT, 2 = VS, 3 = GND Remote control Leaded
Datasheet
Mold 6.0 W x 6.95 H x 5.6 D 56 AGC5 30 0.08 45 0.70 1 = OUT, 2 = GND, 3 = VS Remote control Leaded
Datasheet
Mold 6.0 W x 6.95 H x 5.6 D 56 AGC5 45 0.12 45 0.7 1 = OUT, 2 = VS, 3 = GND Remote control Leaded
Datasheet
Mold 6.0 W x 6.95 H x 5.6 D 56 AGC5 45 0.08 45 0.35 1 = OUT, 2 = VS, 3 = GND RCMM Remote control Leaded
Datasheet
Mold 6.0 W x 6.95 H x 5.6 D 56 AGC5 45 0.08 45 0.35 1 = OUT, 2 = GND, 3 = VS XMP-1, XMP-2 Remote control Leaded
Datasheet
Mold 6.0 W x 6.95 H x 5.6 D 56 AGC5 45 0.12 45 0.7 1 = OUT, 2 = GND, 3 = VS XMP-1, XMP-2 Remote control Leaded
Datasheet
Mold 6.0 W x 6.95 H x 5.6 D 30 AGC6 30 0.08 45 0.70 1 = OUT, 2 = VS, 3 = GND RC-5 Remote control Leaded
Datasheet
Mold 6.0 W x 6.95 H x 5.6 D 30 AGC6 30 0.08 45 0.70 1 = OUT, 2 = GND, 3 = VS Panasonic Remote control Leaded
Datasheet
Mold 6.0 W x 6.95 H x 5.6 D 33 AGC6 30 0.08 45 0.70 1 = OUT, 2 = VS, 3 = GND RC-5 Remote control Leaded
Datasheet
Mold 6.0 W x 6.95 H x 5.6 D 33 AGC6 30 0.08 45 0.70 1 = OUT, 2 = GND, 3 = VS Panasonic Remote control Leaded
Datasheet
Mold 6.0 W x 6.95 H x 5.6 D 36 AGC6 30 0.08 45 0.70 1 = OUT, 2 = VS, 3 = GND RC-5 Remote control Leaded
Datasheet
Mold 6.0 W x 6.95 H x 5.6 D 36 AGC6 30 0.08 45 0.70 1 = OUT, 2 = GND, 3 = VS RC-5 Remote control Leaded
Datasheet
Mold 6.0 W x 6.95 H x 5.6 D 38 AGC6 30 0.08 45 0.70 1 = OUT, 2 = VS, 3 = GND NEC Remote control Leaded
Datasheet
Mold 6.0 W x 6.95 H x 5.6 D 38 AGC6 30 0.08 45 0.70 1 = OUT, 2 = GND, 3 = VS NEC Remote control Leaded
Datasheet
Mold 6.0 W x 6.95 H x 5.6 D 40 AGC6 30 0.08 45 0.70 1 = OUT, 2 = VS, 3 = GND RC-5 Remote control Leaded
Datasheet
Mold 6.0 W x 6.95 H x 5.6 D 40 AGC6 30 0.08 45 0.70 1 = OUT, 2 = GND, 3 = VS Panasonic Remote control Leaded
Datasheet
Mold 6.0 W x 6.95 H x 5.6 D 56 AGC6 30 0.08 45 0.70 1 = OUT, 2 = VS, 3 = GND RCA Remote control Leaded
Datasheet
Mold 6.0 W x 6.95 H x 5.6 D 56 AGC6 30 0.08 45 0.70 1 = OUT, 2 = GND, 3 = VS RCA Remote control Leaded